We are attending AACC 2013 in Houston, TX as an exhibitor during July 29 – August 1. This year we will be presenting TROVA™: the first ever “Open Source” point-of-care test (POCT) system allows ANY existing ELISA to be converted as a POCT within 3 months. See us at booth #4165. Read more about TROVA™ POCT System More information about AACC 2013
OptiMax™ Automation Plates Featured in Drug Discovery World
OptiMax™ Automation Plates Featured in Drug Discovery World Article on Innovative Technologies to Improve ELISA (Click here for details)
Eliminate Cumbersome Wash
Traditional Wash Steps are replaced by Simple Flush of Optimiser™ Microchannels The microchannel at the base of each well only holds ~5 μl of reagent. The small dimensions and low volume capacity of the microchannel can be leveraged to remove cumbersome wash steps within the assay. For instance, after primary antibody binding in conventional plates, a wash step is required. In Optimiser™, when the capture antibody reagent is loaded, it fills the channel and a slight excess volume is drawn out by the capillary pad. The remaining volume is trapped by capillary forces in the microchannel. With Optimiser™, plate “washing” is replaced by a simple pipetting step to add 5 μl of wash buffer to the well. When the wash buffer (any second liquid) is added, the capillary barrier at the microchannel inlet is broken and the pad draws out the capture antibody reagent. Owing to the small cross-section of the channel, there is minimal mixing between the two reagents and the wash buffer effectively “flushes” out the capture antibody reagent. This makes Optimiser™ operations very easy and automation friendly (no wash station)!
Assay times of 2 hours or less
Optimiser™ microchannels have a 10x higher binding efficiency compared to wells of conventional plates. Rate of Primary Antibody Absorption in Optimiser™ Microchannels Rapid binding kinetics eliminates the need for protracted incubations to efficiently coat primary antibody or for the need to purchase pre-coated plates. The incredible binding efficiency in Optimiser™ plates is driven by a 50x increase in surface area to volume ratio as compared to a conventional microplate well. Diffusion distances are also dramatically compressed as the microchannel has a 200 micron by 200 micron working dimension. Overall binding surface of is increased by 50%.
Adjust Sample Volume To Select Benefits You Desire
Detection of Human IL-4
Femtogram Sensitivity
Achieve Femtogram Level Sensitivity without Compromising Sample Volume or Time Optimiser™ Microplates Allow Scientists to Achieve Femtogram Level Sensitivity Using Standard ELISA Protocols and Reagents
Tecan and MiCo BioMed co-market new ELISA system
Click here to read more
MiCo BioMed partners with University of Cincinnati
MiCo BioMed partners with University of Cincinnati to attain $3 Million dollar grant to advance Lab on a Chip technologies to improve patient care involving the testing of body fluids. More Info